商品介绍

 

Description

FluoroVue™ Nucleic Acid Gel Stain (10,000X) is specially designed for in-gel use and is a safer replacement for conventional Ethidium bromide (EtBr), which poses a significant health and safety hazard to its users. It is a fluorescent stain which offers highly sensitive detection of double-stranded or single-stranded DNA and RNA in a convenient manner. FluoroVue™ Nucleic Acid Gel Stain offers high sensitivity that is several times greater than EtBr. 

FluoroVue™ Nucleic Acid Gel Stain is compatible with both conventional UV gel-illumination systems as well as harmless long wavelength blue light illumination systems, like B-BOX™. When bound to nucleic acids, FluoroVue™ Nucleic Acid Gel Stain has a fluorescent excitation maximum of 250 and 482 nm, and an emission maximum of 509 nm. Therefore, it can replace EtBr without the need of changing existing lab imaging systems.

Features:

  • Excellent for in-gel staining

  • Sensitivity: 0.14 ng (DNA) or 1 ng (total RNA)

  • A safer alternative to EtBr

  • Compatibility: suitable to blue or UV light

  • Increased cloning efficiency (blue light)

 

Storage

Protected from light4°C for 12 months-20°C for 24 months

Odoo - Sample 1 for three columns

Sensitivity of FluoroVue™

The FluoroVue™ Nucleic Acid Gel Stain (NS1000) shows a green-yellow fluorescence under blue light excitation. The sensitivity of NS1000 is about 0.14 ng (arrow) for a 4 kb fragment. 

Odoo - Sample 2 for three columns

Excitation and emission spectrum of FluoroVue™ 

FluoroVue™ Nucleic Acid Gel Stain (NS1000) has a fluorescent excitation maxima of ~250 and ~482 nm, and an emission maximum of ~509 nm. Therefore, it can replace EtBr without the need for changing existing lab imaging systems. 

Odoo - Sample 3 for three columns

Non-mutagenicity of FluoroVue™

FluoroVue™ Nucleic Acid Gel Stain (NS1000) is proofed for their safety (non-mutagenicity) using Ames test. However, it must be noted that since solvent may penetrate the skin, it is recommended that users wear gloves when using the fluorescent dyes.

 Contents

Component

Volume

Cat. No.

FluoroVue™ Nucleic Acid Gel Stain (10,000X

500 μl

NS1000

FluoroVue™ Nucleic Acid Gel Stain (10,000X)

5 x 500 μl

NS1001

 

Storage

Protected from light4°C for 12 months-20°C for 24 months

 

Manual

Manual_NS1000_FluoroVue™ Nucleic Acid Gel Stain

SDS

SDS_NS1000

Safety report

Safety report- Ames test

Safety report- cytotoxicity test

 

 

Before opening

Warm the vial to an ambient temperature, then vortex and spin down the content of the vial to ensure the solution is homogeneous.

Working Reagent Preparation

1:10,000 dilution in TAE or TBE buffered agarose 

Odoo - Sample 1 for three columns

In- gel staining

This protocol is highly recommended.

1. Prepare TAE or TBE buffered molten agarose solution.

40 ml molten agarose solution can cast two mini-gels (5.4 x 5.9 cm) or one landscape-gel (10.9 x 5.9 cm).

2. Dilute FluoroVue™ Nucleic Acid Gel Stain 10,000X with the molten gel solution and mix well prior to being poured into the gel. 

For example: 4 μl in 40 ml molten agarose solution

3. Cool the molten agarose solution until it can be handled by hand and then pour it into gel tray.

Casted gels are stable at 4°C for 3 days in dark. After three days the sensitivity will decrease daily. 

4. Perform agarose gel electrophoresis (avoid light).

The recommended voltage is 4–10 V/cm (distance between anode and cathode). Avoid using high voltage during electrophoresis. High voltage causes excess heat and affects the dye adversely. 

During electrophoresis, the staining dye runs toward the anode, therefore DNA bands with smaller molecular weights may be weaker in intensity due to less staining dye. 

5. Visualize or photograph the gel with UV or blue-light illumination (blue-light is recommended).

Clean the surface of the illuminator before and after each use with deionized water. Accumulation of fluorescent dyes on the surface will create a high fluorescent background.

Video cameras and CCD cameras have a different spectral response compared to the black-and-white print film and therefore may not exhibit the same sensitivity.

Odoo - Sample 2 for three columns

Staining during electrophoresis

The sensitivity of this method is slightly lower than the in-gel staining.

1. Prepare agarose gel following your standard protocol.

2. Dilute FluoroVue™ Nucleic Acid Gel Stain 10,000 folds into the running buffer and mix well.

For example: 30 μl in 300 ml running buffer 

3. Perform agarose gel electrophoresis (avoid light).

During electrophoresis, the staining dye runs toward the anode.

4. Visualize or photograph the gel with UV or blue-light illumination (blue-light is recommended).

Clean the surface of the illuminator before and after each use with deionized water. Accumulation of fluorescent dyes on the surface will create a high fluorescent background.

Video cameras and CCD cameras have a different spectral response compared to the black-and-white print film and therefore may not exhibit the same sensitivity.

Odoo - Sample 2 for three columns

Staining after electrophoresis (post-staining)

Post-staining method is recommended for polyacrylamide electrophoresis, due to the longer time required for running PAGE. The sensitivity of this method is lower than the in-gel staining method.

1. Performing agarose gel electrophoresis following your standard protocol.

 2. Dilute FluoroVue™ Nucleic Acid Gel Stain 10,000 folds into the TE, TAE, or TBE buffer and mix well.

For example: 10 μl in 100 ml TAE buffer 

Use a plastic container. Glass containers are not recommended, as they absorb fluorescent dye in staining solution. 

Protect the staining container from light by covering it with aluminium foil, or place it in the dark.

The staining solution can be stored for up to one week or more.

3. Immerse the gel in a staining solution (1X) and incubate at room temperature for 10 - 30 minutes. (avoid light).

Staining time varies with the thickness of the gel and percentage of agarose. If needed, agitate the gel gently at room temperature to shorten staining time. 

4. Visualize or photograph the gel with UV or blue-light illumination (blue-light is recommended).

Clean the surface of the illuminator before and after each use with deionized water. Accumulation of fluorescent dyes on the surface will create a high fluorescent background.

Video cameras and CCD cameras have a different spectral response compared to the black-and-white print film and therefore may not exhibit the same sensitivity.

 

Epidemiology and clinical features of viral anterior uveitis in southern Taiwan—diagnosis with polymerase chain reaction

Yu-Ting Hsiao,1 Ming-Tse Kuo,2 Wei-Yu Chiang,2 Tsai-Ling Chao,3 and Hsi-Kung Kuo BMC Ophthalmol. 2019; 19: 87. Published online 2019 Apr 3. doi: 10.1186/s12886-019-1093-2

PMCID: PMC6448235

Odoo - Sample 3 for three columns

B-BOX™ Blue Light LED Epi-illuminator

  • 470 nm long wavelength

  • Improved cloning efficiency 

  • Compact, light-weight, and portable (less than 1 kg)

  • Adjustable and removable filter plate allows for gel cutting, visualization, and documentation

Odoo - Sample 1 for three columns

ExcelBand™ DNA Ladder series

  • Sharp bands

  • Quick reference enhanced bands 

  • Ready-to-use— premixed with loading dye for direct loading

  • Stable— room temperature storage over 6 months

Odoo - Sample 3 for three columns

FluoroStain™ DNA Fluorescent Staining Dye

  • Excellent for post staining

  • Sensitivity up to 0.04 ng DNA

  • A safe alternative to EtBr

  • Suitable for blue or UV light

 

品牌介绍
SMOBIO的B-BOX™是一种长波长蓝光LED落射照明器。它设计紧凑,结构坚固。B-BOX™落射照明器由于其非紫外线光源和低至12伏的低工作电压,并且为非致癌DNA /蛋白质染料提供了工作能力,因此为用户提供了前所未有的安全性。B-BOX™带有高质量的非闪烁LED灯,对DNA和蛋白质染料高度敏感。B-BOX™可以极大地减轻凝胶提取的日常琐事,即使在明亮的环境光下也可以轻松进行可视化和凝胶切割。多角度滤板(目录号VE0102)为凝胶切割,可视化和记录提供了最佳角度。B-BOX™还带有用于过滤和可视化的琥珀色滤镜(目录号VE0103)。Phox™Photobox(目录号 VE0104)为使用任何智能手机拍摄的图像提供了一个迷你暗室环境。最后,工作区域周围的内置屏障系统有助于清洁。特征提高克隆效率 紧凑,轻巧和便携式(重量不足1千克)安全功能包括:470 nm长波长,对用户没有任何紫外线辐射危害与非致癌,非溴化乙锭的DNA染料兼容用户友好:样品易于观察(使用滤板或护目镜时) LED光源持续长达50,000小时出色的检测灵敏度:使用FluoroStain™DNA荧光染色染料时,DNA≤0.04 ng,使用FluoroStain™蛋白荧光染色染料时,蛋白≤3ng(与银染一样灵敏)可调和可移动的滤板可进行凝胶切割,可视化和记录内置屏障设计,易于清理在明亮的环境光下可见借助其自身的内置散热器,强调了最小的功率依赖,低发热